logo

SKU: NOVA-512962-REV

NEXTFLEX RiboNaut rRNA depletion (HMR)

Increase the representation of relevant transcripts

Dry Ice

Resources

PDF

Manual

PDF

Fact Sheet

Flyer RNA-seq Portfolio

Description

The NEXTFLEX™ RiboNaut™ rRNA Depletion Kit (Human/Mouse/Rat) removes both cytoplasmic and mitochondrial rRNA from total RNA to free sequencing reads for informative transcripts, including non-polyadenylated RNAs, across human, mouse, and rat samples. The workflow uses subtractive hybridization with biotinylated probes and streptavidin-coated magnetic beads.

  • Broad transcript detection: Preserves mRNA and non-poly(A) RNA species for total RNA-seq and differential expression studies
  • Flexible input: From 5 ng to 1 µg total RNA
  • Straightforward workflow: Subtractive hybridization with biotinylated probes and magnetic-bead capture
  • Seamless downstream integration: Compatible with essentially any RNA-seq library-prep system, including NEXTFLEX Rapid Directional RNA-Seq 2.0
  • Subsequent libraries can be sequenced on any platform
  • Throughput ready: Works manually or on common liquid handlers, including Sciclone™ and Zephyr™ workstations

HMR rRNA depletion via subtractive hybridization

The NEXTFLEX RiboNaut rRNA Depletion Kit (Human, Mouse, Rat) uses a subtractive hybridization workflow to remove ribosomal RNAs, which constitute ~ 80 - 90% of total RNA preparations. A mixture of biotinylated oligonucleotides complementary to cytoplasmic and mitochondrial rRNA in human, mouse, and rat total RNA samples is hybridized to the sample, then captured with streptavidin-coated magnetic beads to pull down rRNA:probe complexes. The supernatant contains rRNA-depleted RNA suitable for total RNA-seq with detection of mRNA and non-poly(A) transcripts. The protocol is optimized for 5 ng to 1 µg total RNA and integrates seamlessly with any RNA-seq library-prep workflow.

Nex Ribonaut Workflow

Figure 1. Workflow for HMR rRNA depletion with the NEXTFLEX RiboNaut kit. Biotinylated baits hybridize to cytoplasmic and mitochondrial rRNA in human, mouse, and rat. Streptavidin magnetic beads capture rRNA:probe complexes, followed by magnetization, cleanup, and elution to yield rRNA-depleted RNA ready for RNA-seq library prep.

When to use rRNA depletion

For broad transcriptome profiling, rRNA depletion removes 5S, 5.8S, 18S, 28S (cytoplasmic) and 12S, 16S (mitochondrial) rRNA while preserving mRNA and non-poly(A) RNAs, standardizing inputs for total RNA-seq across human, mouse, and rat. Use rRNA depletion when RNA is partially degraded or low, when you need lncRNA and other non-poly(A) species, or when tissues are ribosome rich. Choose poly(A) selection such as NEXTFLEX Poly(A) Beads 2.0 kit when the study targets polyadenylated mRNA from high-quality RNA. 

Performance metrics after ribodepletion

The NEXTFLEX RiboNaut rRNA Depletion Kit (Human, Mouse, Rat) delivers consistent performance for total RNA-seq after depletion. Example datasets show uniform gene body coverage and minimal residual rRNA contamination across human, mouse, and rat total RNA. Inputs from 5 ng to 1 µg generate rRNA-depleted RNA for stranded RNA-seq library prep.

Nex Ribonaut Fig2 Gene Body Coverage After Hmr Rrna Depletion

Figure 2. Uniform gene body coverage after HMR rRNA depletion. rRNA-depleted total RNA prepared with the NEXTFLEX RiboNaut rRNA Depletion Kit (Human, Mouse, Rat) shows even coverage along transcripts from 5′ to 3′ at 1000 ng, 100 ng, and 5 ng inputs. Libraries were constructed with NEXTFLEX Rapid Directional RNA-Seq 2.0 and sequenced to a common read depth, yielding overlapping coverage profiles across inputs.

Uniform gene body coverage indicates that depletion and library construction introduce minimal bias, which supports accurate total RNA-seq quantification and isoform analysis. Consistency at low input strengthens performance for scarce or partially degraded HMR samples.

Nex Ribonaut Fig3 Low Residual Rrna After Hmr Rrna Depletion

Figure 3. Low residual rRNA after HMR rRNA depletion. Total RNA (Universal Human Reference RNA) was processed with the NEXTFLEX RiboNaut rRNA Depletion Kit (Human, Mouse, Rat). Libraries were prepared using the NEXTFLEX Rapid Directional RNA-Seq 2.0 kit and sequenced on an Illumina® MiSeq® (1×151) platform. Low levels were observed across 5S, 5.8S, 12S, 16S, 18S, and 28S rRNA species, covering both cytoplasmic and mitochondrial rRNA.

Low residual rRNA means more usable reads for genes and non-poly(A) transcripts in total RNA-seq, improving sensitivity and quantification. Reducing both cytoplasmic and mitochondrial rRNA supports consistent performance across HMR samples and input amounts.

Seamless integration with the NEXTFLEX RNA ecosystem for total RNA-seq

The NEXTFLEX RiboNaut rRNA Depletion Kit (Human, Mouse, Rat) plugs into Revvity's broader NEXTFLEX RNA-seq accessory portfolio. After subtractive hybridization and magnetic capture, the resulting rRNA-depleted RNA moves directly into NEXTFLEX Rapid Directional RNA-Seq 2.0. Indexing can be scaled from pilot runs to 384-plex using UDI  or UDI-UMI  plates that are color balanced  and QC verified  to help limit index misassignment in large pools. The end-to-end workflow supports 5 ng to 1 µg inputs and scales from low-input discovery to high-throughput studies on Illumina® and Element® systems.

Automation support

Validated scripts for Revvity Sciclone and Zephyr workstations standardize hybridization, bead capture, and cleanup to reduce hands-on time and variability. Volumes and steps are automation friendly, and the rRNA-depleted RNA transfers directly into automated NEXTFLEX library preparation while maintaining rRNA removal efficiency and strandedness.

Catalog Number
NOVA-512962-REV
Name
NEXTFLEX RiboNaut rRNA depletion (HMR)
Price(48 rxn(s))
Pack Size
← Back to products