SKU: NOVA-802100-REV
NEXTFLEX Cas9 Depletion Enzyme (Globin)
Recover informative reads - Targeted globin depletion for human blood RNA-seq
Resources
Datasheet
Fact Sheet
Description
Globin depletion enzyme for human blood RNA-seq libraries that removes hemoglobin-derived dsDNA fragments to improve transcriptome coverage.
- Increase usable sequencing depth by reducing globin-derived reads before sequencing
- Preserve existing RNA-seq workflows with a standalone module used at the dsDNA stage
- Simplify setup with a ready-to-use Cas9-gRNA complex, RNase inhibitor, and 10X Cas9 Buffer
- Accelerate depletion with a 1-hour reaction and approximately 5 minutes hands-on time
- Integrate into manual or automated short- and long-read sequencing workflows
Product Details
Targeted globin depletion for more informative human blood RNA-seq data
NEXTFLEX Cas9-gRNA Globin Depletion Enzyme (Human) (NOVA-802100) is designed to remove globin-derived sequences from human blood RNA-seq libraries. In whole blood and blood-derived samples, highly abundant globin transcripts can consume a substantial share of mapped reads and reduce sensitivity for lower-abundance transcripts. This globin depletion enzyme redirects sequencing capacity toward non-globin genes without requiring a change in library preparation chemistry.
DASH-style CRISPR-Cas9 cleavage at the dsDNA library stage
The enzyme uses a DASH-style Depletion of Abundant Sequences by Hybridization approach in which Cas9-gRNA complexes cleave unwanted target molecules after conversion to double-stranded DNA. Depletion can be performed immediately after second-strand synthesis or on completed libraries, depending on the workflow. Acting at the dsDNA stage helps avoid additional RNA-handling steps and supports use with challenging or partially degraded blood-derived material.
Pre-complexed guide pool against human hemoglobin loci
NEXTFLEX Cas9-gRNA Globin Depletion Enzyme is supplied as a pre-complexed Cas9-guide RNA mixture containing 30 guide RNAs. The guide pool targets the human HBA1, HBA2, HBB, and HBD loci to selectively cleave hemoglobin-derived library fragments while retaining non-globin transcripts. The format includes integrated RNase inhibitor and 10X Cas9 Buffer for direct incorporation into depletion reactions.
Workflow-independent placement for bulk and single-cell RNA-seq
Because the module is standalone rather than embedded in a fixed library preparation kit, NEXTFLEX Cas9-gRNA Globin Depletion Enzyme can be introduced into existing bulk or single-cell RNA-seq workflows once libraries have reached the dsDNA stage. It is positioned for compatibility with commercial or in-house library preparation methods and supports both short-read and long-read sequencing strategies. The product is also listed as automation compatible for laboratories standardizing manual or liquid-handling workflows.
Defined unit input for controlled depletion setup
One unit is defined as the amount required to deplete 1-10 ng of target dsDNA library. This definition assumes a library size of ≥400 bp, typically corresponding to an insert size of approximately 300 bp or greater. The NOVA-802100 configuration provides 50 µL of enzyme and is shipped on dry ice.
Supporting Data

Figure 1. Globin depletion with NEXTFLEX Cas9-gRNA Globin Depletion Enzyme (Human) increases informative reads in blood RNA-seq libraries. Stacked bar chart shows the percentage of mapped reads assigned to globin genes (purple) and non-globin genes (green) in untreated and Cas9-depleted libraries. In untreated libraries, globin transcripts account for nearly half of mapped reads, whereas after Cas9 globin depletion almost all mapped reads align to non-globin genes.