logo

SKU: A51008-ARI

Arima-HiC+ Kit

Accurate and Reproducible Genome Conformation Analyses (Epigenetics)

Blue Ice

Resources

PDF

Datasheet

HiC Genome Conformation Analyses

PDF

Application Note

Application Note Low Input

Video

Video

Arima-HiC: A simple and robust Hi-C workflow

Description

The Arima-HiC approach uses a highly simplified and robust protocol that streamlines Hi-C to be a 6 hour workflow followed by library prep and and next-generation sequencing. Arima-HiC empowers researchers to leverage Hi-C technology to perform genome-wide and targeted indentification of promotor-enhancer interactions, link non-coding disease-associated variants to target promotors, and uncover how pertubations in genome conformation impact gene regulation in diseases contexts.  

  • Proven Performance - greater accuracy of chromatin loop and topological domain detection even at reduced sequencing depths
  • Fast and user-friendly workflow - rapid 6 hour HiC-workflow
  • Assured quality - rapid and easy library QC steps that accurately predict library quality, ensuring sequencing success
  • Flexible input requirements - support for a broad range of sample types and an optimized protocol for low sample input

Arima-HiC also empowers researchers to leverage HiC-technology to detect and correct misjoin errors in draft assemblies, assign contigs to chromosomes de novo and order and orient contigs into chromosome scale scaffolds. It has been successfully performed on a wide-range of species from the plant and animal kingdoms. 

Arima-HiC Workflow Overview

Chromatin from a sample source (tissues, cell lines, or blood) is first crosslinked to preserve the genome sequence and structure. The crosslinked chromatin is digested using a restriction enzyme (RE) cocktail. The 5’-overhangs are then filled in, causing the digested ends to be labeled with a biotinylated nucleotide. Next, spatially proximal digested ends of DNA are ligated, capturing the sequence and structure of the genome. The ligated DNA is then purified, producing pure proximally-ligated DNA. The proximally-ligated DNA is fragmented, and the biotinylated fragments are enriched. The enriched fragments are subjected to a custom library preparation protocol utilizing a range of supported commercially available library prep kits. Depending on the choice of library prep kit, a separate Arima-HiC Library Prep user guide is provided that contains a custom protocol for converting proximally-ligated DNA to Arima-HiC libraries.

 

Hic Workflow

Sequencing and Data Analysis

Arima-HiC libraries are sequenced via Illumina® sequencers in “paired-end” mode. The tools necessary for analyzing the resulting data depend on the application.

Applications

  • Identification and visualization of TADs, loops, or other features (see data sheet)

Specifications

Hic Assayspecs

Catalog Number
A51008-ARI
Name
Arima-HiC+ Kit
Price(8 rxn(s))
Pack Size
8 rxn(s)
← Back to products