ExoMS Surface Protein Capture Kit (Serum/Plasma EVs)

Delivering sensitive protein detection through reduced protein carryover

Product Description

Take advantage of powerful LC/MS proteomics approaches to study the biology of surface-associated extracellular vesicle (EV) proteins (the surfeome) and to identify EV surface biomarkers using SBI’s ExoMSTM Surface Protein Capture Kit (Serum/Plasma). The kit provides a fast, well-validated, and robust method for selectively capturing surface and membrane-associated proteins from EVs that have already been isolated from serum or plasma, enabling proteomics studies of this important subset of EV proteins. Because of the low residual protein carryover delivered by this kit, you get increased detection of low-abundance biomarkers that are often missed using traditional approaches.

  • Unique—the only commercially available kit that specifically captures exosome surface and membrane proteins
  • Sensitive—removes many common contaminants from EV preps, such as albumin and IgG, for improved biomarker detection by LC/MS
  • Compatible—works with EVs isolated using a variety of methods including ExoQuick®, ExoQuick® PLUS, ultracentrifugation, and most column-based kits sold by other vendors
  • Fast—go from isolated sample to LC/MS in less than 5 hours

 ExoMS Protein Capture Technology

SBI's robust protein capture technology is based on an affinity purification strategy (ExoMS Total Protein Capture Kit) or a two-step biotinylation and bead capture process (ExoMS Surface Protein Capture Kit for plasma/serum or ExoMS Surface Protein Capture Kit for tissue culture) that efficiently sequesters surface and membrane proteins away from internal EV proteins. The result is a protein preparation significantly enriched in membrane-associated proteins (Figure 1).

Exoms Enriched Membrane Associated Proteins

Figure 1. Membrane-associated proteins are enriched in human serum EV samples processed with the ExoMS Surface Protein Capture Kit compared to samples processed with the ExoMS Total Protein Capture Kit.

In addition, the ExoMS Surface Protein Capture Kit is able to deliver sensitive biomarker detection through the use of a proprietary, affinity-based resin that traps many of the carryover-proteins commonly co-isolated with EVs, but which are not actually carried in or on the surface of EVs (Figure 2). Reduction of these protein contaminants, such as albumin and IgG, reduces their strong signal during mass spec analysis, enabling improved detection of more relevant but lower-abundance proteins.

Exoms Reduced Carryover Proteins

Figure 2. Common carryover proteins are reduced in human serum EV samples processed with the ExoMS Kit compared to samples processed using a standard protocol.

Supporting Data

Proteins identified from an ExoMS Surface Protein Capture Kit-prepared sample

See the 25 most abundant membrane-associated proteins identified by LC/MS from a human serum EV sample prepared with the ExoMS Surface Protein Capture Kit. Highlighted entries are proteins which were identified from a sample prepared using the ExoMS Surface Protein Capture Kit and not detected in comparable MS analysis of total EV protein from isolated exosomes, demonstrating the enhanced sensitivity and capability provided by the ExoMS kit for detecting surface and membrane-associated EV proteins.

Exoms Table 1 2

Denotes surface or membrane-associated protein identified using the ExoMS Surface Protein Capture kit but not detected in comparable MS analysis of total EV protein from isolated exosomes


Exosomal protein profiling using mass spectrometry is also available as convenient Exosome Proteomics Services.

  • Catalog Number
    EXOMS100A-4-SBI
  • Supplier
    SBI System Biosciences
  • Size
  • Shipping
    Blue Ice
Price
653,00 €